BT Versatility Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach ISDN-Zugriffsgeräte BT Versatility herunter. BT Versatility User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 59
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Ofces Worldwide
The telecommunications services described in this publication
are subject to availability and may be modied from time to time.
Services and equipment are provided subject to British
Telecommunications plc’s respective standard conditions of
contract.
Nothing in this publication forms any part of any contract.
© British Telecommunications plc 2003
Registered ofce: 81 Newgate Street, London EC1A 7AJ
Registered in England No. 1800000
Printed in Ireland
PHME 42396/01/04
Part No. 2734.31000-2
Printed on paper which meets international environmental standards
The CE Marking on this equipment indicates
Compliance with the following
This device conforms to Directive 1999/5/EC on
Radio Equipment and Telecommunications
Terminal Equipment as adopted by the
European Parliament And Of The Council
Installation and
Maintenance
Manual
BT Versatility
Communications without
the complications
Installation.indd 3/12/2004, 2:12 PM1
Seitenansicht 0
1 2 3 4 5 6 ... 58 59

Inhaltsverzeichnis

Seite 1 - BT Versatility

Ofces WorldwideThe telecommunications services described in this publication are subject to availability and may be modied from time to time.Service

Seite 2 - Contents

BT Versatility Installation and Maintenance Manual 9 Mounting the CCU The CCU is mounted on the bracket by sliding it on from the left hand side. T

Seite 3 - Introduction

BT Versatility Installation and maintenance Manual 10 Modules located in the CCU There are a number of modules that can be installed in the CCU.

Seite 4

BT Versatility Installation and Maintenance Manual 11System Expansion To equip the switch with more than 8 extensions or to add an Internet or Optio

Seite 5

BT Versatility Installation and maintenance Manual 12Mounting the Backplane Slide the backplane on from the right hand side. Ensure the connector

Seite 6

BT Versatility Installation and Maintenance Manual 13Expansion Modules There are three types of expansion module that can be installed on the back

Seite 7 - Installation checklist

BT Versatility Installation and maintenance Manual 14Installing an Expansion module Install the Backplane as described on page 12. Install the M

Seite 8 - CCU Location(CCU)

BT Versatility Installation and Maintenance Manual 15 Analogue line module The Analogue Line module contains circuitry for 2 Analogue Lines. The mod

Seite 9 - 300mm min

BT Versatility Installation and maintenance Manual 16 To Locate the Analogue Module in the Ports Module: Remove the Ports Module by firstly openin

Seite 10 - Mounting the CCU

BT Versatility Installation and Maintenance Manual 17Digital Line Module (ISDN 2) Basic Rate ISDN expansion module The ISDN Basic Rate Module provid

Seite 11 - Modules located in the CCU

BT Versatility Installation and maintenance Manual 18 To Locate the Digital Line Module (ISDN 2) in the PORTS module Remove the Ports Module by fi

Seite 12 - System Expansion

BT Versatility Installation and maintenance Manual 1Contents Introduction 2 General overview 2 Safety Precautions during installation and s

Seite 13 - Mounting the Backplane

BT Versatility Installation and Maintenance Manual 19System ISDN settings The system can be configured with 8 Basic Rate ISDN interfaces. Half of th

Seite 14 - Expansion Modules

BT Versatility Installation and maintenance Manual 20Voicemail module The Voice module is coloured BLUE It is located in the Voice Module slot in

Seite 15

BT Versatility Installation and Maintenance Manual 21Primary Rate Interface (Availability TBC) The Primary rate ISDN Module (30B+D) is coloured Yell

Seite 16 - Analogue line module

BT Versatility Installation and maintenance Manual 22Connecting the battery backup unit to the system The Battery back up provides operation of an

Seite 17

BT Versatility Installation and Maintenance Manual 23 Connecting the Battery Ensure the battery switch on the BBU unit is turned off. • This switc

Seite 18

BT Versatility Installation and maintenance Manual 24 Featurephone V16 V16 Featurephone connections (underside of phone)

Seite 19

BT Versatility Installation and Maintenance Manual 25 Featurephone V8 V8 Featurephone connections (underside of phone) Handset conn

Seite 20 - System ISDN settings

BT Versatility Installation and maintenance Manual 26 Attaching the Featurephone desk plinth (V8 and V16) Position at 35 degrees Positio

Seite 21 - Voicemail module

BT Versatility Installation and Maintenance Manual 27V16 expansion console The V16 featurephone can be equipped with a 32 key module. This provides

Seite 22

BT Versatility Installation and maintenance Manual 28 Clip, Plinth and installation of the V16 expansion console NOTE: For the 20 degrees p

Seite 23

BT Versatility Installation and maintenance Manual 2Introduction This document describes the practices to be adopted by field engineers during ins

Seite 24 - Connecting the Battery

BT Versatility Installation and Maintenance Manual 29 Wall-mounting a Featurephone The phone plinth is inverted on the base to wall mount the phone

Seite 25 - Featurephone V16

BT Versatility Installation and maintenance Manual 30 Door Intercom The door intercom is connected to extension 23, the fourth ex

Seite 26 - Featurephone V8

BT Versatility Installation and Maintenance Manual 31Cabling the unit All Line and Extension circuit cabling is inserted from the top of the unit. T

Seite 27

BT Versatility Installation and maintenance Manual 32Four wires per Extension are connected at the Main Equipment. Spare wires must be neatly lai

Seite 28

BT Versatility Installation and Maintenance Manual 33CCU connections The CCU has the following connectors:- • Eight four way Krone connectors for t

Seite 29 - Cord Rail

BT Versatility Installation and maintenance Manual 34• The MOH Module may be used with all Systems provided they are running above software versi

Seite 30 - Wall-mounting a Featurephone

BT Versatility Installation and Maintenance Manual 35• Two 2 pole switches are also provided for the 100 ohm terminating resistance for the ISDN Ba

Seite 31 - Door Intercom

BT Versatility Installation and maintenance Manual 36Options Module MDF Connections The options module is equipped with a stereo jack for an ‘exte

Seite 32 - Cabling the unit

BT Versatility Installation and Maintenance Manual 37Expanding an Existing system Modules may be removed and re-inserted in a system without disconn

Seite 33 - D Data - LJU Pin 6

BT Versatility Installation and maintenance Manual 38Maintenance procedures Faults can be rectified on site by replacing faulty modules or PCBs H

Seite 34

BT Versatility Installation and Maintenance Manual 3Safety Precautions during installation and system upgrades Always unplug or isolate the mains s

Seite 35 - Ports Module MDF Connections

BT Versatility Installation and Maintenance Manual 39Replacing a faulty Module MDF To replace a faulty MDF of a Ports, Internet or Options module th

Seite 36

BT Versatility Installation and maintenance Manual 40 Replacing Faulty PCBs Replacing the 008 extension board If a fault occurs on the first eigh

Seite 37 - External Extension

BT Versatility Installation and Maintenance Manual 41 Replacing the CCU Control PCB This PCB is NOT hot swappable. The System must be powered down t

Seite 38 - Expanding an Existing system

BT Versatility Installation and maintenance Manual 42 Power supply unit spare fuse A spare mains fuse is located in the Power supply unit. It is i

Seite 39 - Maintenance procedures

BT Versatility Installation and Maintenance Manual 43Replacing the Power Supply Unit The procedure to be used when replacing the Power Supply unit i

Seite 40

BT Versatility Installation and maintenance Manual 44Replacing the CCU MDF This PCB is NOT hot swappable. The System must be powered down to chang

Seite 41 - Replacing Faulty PCBs

BT Versatility Installation and Maintenance Manual 45Power fail When planning the extension wiring for the system, consideration should be given to

Seite 42

BT Versatility Installation and maintenance Manual 46Power up and test • Ensure the mains plug is fitted with a 3A fuse. Switch on • Power up th

Seite 43 - Power supply unit spare fuse

BT Versatility Installation and Maintenance Manual 47Programming Essential programming is carried out either from a Featurephone connected to exten

Seite 44

BT Versatility Installation and maintenance Manual 48Call Barring Extensions are entered into different Classes for barring purposes. There are 6

Seite 45 - Replacing the CCU MDF

BT Versatility Installation and maintenance Manual 4 BT Versatility - Packages, Spares and Maintenance Items BT Code BT Versatility Pro. P

Seite 46 - Power fail

BT Versatility Installation and Maintenance Manual 49Internet Module Programming The Internet Module can only be programmed from the BT Versatility

Seite 47 - Commissioning

BT Versatility Installation and maintenance Manual 50• The following screen is displayed • If an ADSL line is connected to the Internet module

Seite 48 - Programming

BT Versatility Installation and Maintenance Manual 51• Enter the Username. This will be provided by the ISP. • Enter the Password. This will be pr

Seite 49

BT Versatility Installation and maintenance Manual 52Recommendations for customer training As part of the installation, the customer is entitled t

Seite 50 - Installation Wizard

BT Versatility Installation and Maintenance Manual 53Troubleshooting All faults can normally be traced quite readily to a particular PCB. Prior to r

Seite 51

BT Versatility Installation and maintenance Manual 54Technical specification Type of system Hybrid/PBX ISDN 2 line Max 4 ISDN (2B+D) Basic Rate

Seite 52

BT Versatility Installation and Maintenance Manual 55External Music on hold Stereo jack connector (on Options Module) Input impedance 10k ohm Nomin

Seite 53

BT Versatility Installation and maintenance Manual 56ISDN Access to B-channels on PABX PPP, MLPPP, BACP Protocols IP V4 Authentication PAP/CHAP D

Seite 54 - Troubleshooting

BT Versatility Installation and Maintenance Manual 57INDEX 20 degrees, 27 35 degrees, 27 additional modules, 38 ADSL, 7, 36, 50, 51 Analogue, 46 A

Seite 55 - Technical specification

Ofces WorldwideThe telecommunications services described in this publication are subject to availability and may be modied from time to time.Service

Seite 56 - Charcoal ref: Pantone 432C

BT Versatility Installation and Maintenance Manual 5BT Versatility 8 Port Extension Module VDS 007225 BT Versatility Hospitality Application VDS

Seite 57

BT Versatility Installation and maintenance Manual 6BT Versatility Options MDF MTC 007261 BT Versatility Mod Retentn Long 1/4 turn Screw MTC 00

Seite 58

BT Versatility Installation and Maintenance Manual 7Installing the Central Control Unit CCU Location(CCU) The CCU is intended for installation in a

Seite 59

BT Versatility Installation and maintenance Manual 8 CCU Mounting bracket clearances The main unit is mounted on a wall using the bracket supplied

Kommentare zu diesen Handbüchern